Search results for "Glucose oxidase"
showing 10 items of 18 documents
Optimization of the enzyme power source for a nano drug delivery system fuelled by glucose in blood plasma
2019
A unique in vivo electrical pulse generator to improve membrane permeability for drugs and simultaneously facilitate self-powered nano devices for nano drug delivery systems (NDDS) was identified. The use of an unsupported biological catalyst component of the power supply was aimed at the NDDS instead of a conventional membrane electrode assembly (MEA). Self-powered carriers of drugs and prodrugs with improved controlled release capability to target areas using substrate available in biological matrices such as glucose in blood is envisaged. The experimental application implemented prototype designed chambers allowing the entry of premixed precursors and low ohm resistance due the absence o…
Can saliva offer an advantage in monitoring of diabetes mellitus? - A case control study
2014
Objectives: Diabetes Mellitus is emerging as a major health problem over these years. Present method of blood glucose monitoring by venepuncture is invasive leading to reduced patient compliance and thereby ineffective judicious monitoring. The need of the hour is to direct research in the direction of establishing painless and more acceptable blood glucose analysis method.The objective of the study is to conduct a comparative analysis of the concentrations of salivary glucose and blood glucose in type 2 diabetes mellitus patients. Study Design: This study assessed glucose levels using the glucose oxidase method in blood and unstimulated sali - va in 90 subjects who were divided into 3 equa…
Glucose oxidase as a biocatalytic enzyme-based bio-fuel cell using Nafion membrane limiting crossover
2013
A novel combination for an Enzyme-based Biofuel cell included a Nafion membrane as an ion transporter that maintained a working cell charge and inhibited membrane degradation. The prototype cell chamber used oxygen (O2) in the cathode cell and glucose in the anode. The Nafion membrane stability studied here was evidently in the region of 0% loss of conductivity as the charge was constant and increased after the addition of glucose. The prototype cell chamber used NaCl in the cathode cell and glucose oxidase (GOx) in the anodic chamber was successfully studied for membrane stability showed in this study no evidence of poisoning from membrane leakage in a controlled pH environment. There was …
Inkjet printing methodologies for drug screening
2010
We show for the first time a contactless, low-cost, and rapid drug screening methodology by employing inkjet printing for molecular dispensing in a microarray format. Picoliter drops containing a model substrate (D-glucose)/ inhibitor (D-glucal) couple were accurately dispensed on a single layer consisting of the enzymatic target (glucose oxidase) covalently linked to a functionalized silicon oxide support. A simple colorimetric detection method allowed one to prove the screening capability of the microarray with the possibility to assay with high reproducibility at the single spot level. Measurements of the optical signal as a function of concentration and of time verified the occurrence a…
pH control of the production of recombinant glucose oxidase in Aspergillus nidulans.
2004
Aims: Recombinant Aspergillus nidulans sVAL040, capable of synthesizing and secreting glucose oxidase derived from Aspergillus niger was used to study the influence of pH and carbon source on enzyme production. Methods and Results: Glucose oxidase gene (goxC) was expressed under transcriptional regulation by using the promoter of A. nidulans xlnB gene (encoding an acidic xylanase). A maximum specific glucose oxidase activity of approx. 10 U mg−1 protein and a maximum volumetric productivity of 29·9 U l−1 h−1 were obtained at pH 5·5, after 80 h of growth by using xylose as inducer. Enzyme volumetric productivity increased when xylans were used instead of xylose; however, specific glucose o…
On the Relationship between Jetted Inks and Printed Biopatterns:Molecular-Thin Functional Microarrays of Glucose Oxidase
2009
Arrays of circular spots of glucose oxidase have been obtained on functionalized silicon oxide by piezoelectric inkjet printing and the enzymatic activity toward glucose recognition has been monitored. The addition of glycerol to the molecular ink allows to obtain high spot definition and resolution (tens of micrometers wide; one molecule tall), but in spite of its well-known structural stabilizing properties, in dynamic conditions it may lead to increased protein stresses. The jetting voltage and pulse length have been found to be critical factors for both activity retention and pattern definition. High voltages and pulse lengths results in stress effects along with the loss of activity, w…
Glucose-triggered release using enzyme-gated mesoporous silica nanoparticles.
2013
[EN] A new gated nanodevice design able to control cargo delivery using glucose as a trigger and cyclodextrin-modified glucose oxidase as a capping agent is reported.
A Microassay for Measuring Glycogen in 96-Well-Cultured Cells
1996
Abstract This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1,4-α- D -glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this me…
Whispering gallery mode resonator and glucose oxidase based glucose biosensor
2020
Abstract In this research whispering gallery mode resonators (WGMRs) were applied in new concept of glucose sensor based on the shift of WGM resonance frequency induced by enzymatic oxidation of glucose by glucose oxidase (GOx), which was immobilized on WGM-resonator surface. During the enzymatic reaction catalyzed by GOx electrons from glucose via GOx are transferred towards co-immobilized gold nanoparticles (Au-NPs). WGM-resonators were fabricated from standard telecommunication optical-fiber melted in a hydrogen flame. Whispering gallery mode resonance based optical signals generated by these WGM-resonators were evaluated. These WGM-resonators, which were characterized by sufficient qual…
Scanning electrochemical microscopy and electrochemical impedance spectroscopy-based characterization of perforated polycarbonate membrane modified b…
2021
Abstract In this research, scanning electrochemical microscopy (SECM) and electrochemical impedance spectroscopy (EIS) were applied for the evaluation of surface characteristics of electrochemical (amperometric) biosensor based on two composite structures consisting of perforated polycarbonate membrane modified by carbon-nanomaterials and glucose oxidase. The first structure consisted of the polycarbonate filter membrane, punctured by 400 nm holes (PCM) consequently modified with single walled carbon nanotubes (SWCNT) and graphene oxide (GO) layer (PCM/SWCNT/GO); and the other structure consisted of the same PCM, consequently modified with SWCNT and reduced graphene oxide (rGO) layer (PCM/S…